Five Product Lines, Kitted to Your BOM
The ranges below are our standard supply scope for quick reference. Exact models, materials, certifications and packing are set by the quotation and technical agreement; unlisted items can be quoted on request.

Rooftop & Process AC Units
Rooftop and inverter rooftop units are the core, extending to cleanroom packaged units and special models for oilfield and high-temperature process duty. Airflow, external static pressure and corrosion class are set per project, with assembly and power-up testing before dispatch.

Air-Cooled Chillers & Dry Coolers
V-coil dry coolers are the main product: copper-tube aluminium-fin coils, low-noise axial fans and coated frames, laid out to heat load and available space. Air-cooled chillers serve process and comfort cooling, and can pair with dry coolers for free cooling to cut annual energy use.

Water-Source Heat Pumps & Heating Packages
Water-source heat pumps, central heating units and heat-recovery packages. The photo shows a district-heating rooftop array: multiple units in parallel, zoned by building or area. Selection depends on water temperatures, load profile and available roof area.

Water-Cooled Chillers & Ground-Source Heat Pumps
Water-cooled screw and scroll chillers with cooling towers, pumps and controls for process and comfort cooling; ground- and water-source heat pumps for building heating, cooling and district heating, with combined duty from one package. Selection follows capacity, water temperatures, ground-loop or well conditions and the annual load curve; units ship in modules with piping connections pre-set to drawings.

Piping, Consumables & Spares
The items most often missing on site: copper pipe, aluminium and elastomeric insulation, valves, flanges, gauges and brackets, plus compressor, reversing-valve and expansion-valve spares. They ship with the units or separately to the install team.
Direction First, Details Next
Indicative ranges only, not a basis for acceptance; formal data follows the technical agreement and unit documents.
| Category | Typical Range | Common Configuration | Supply Form |
|---|---|---|---|
| Rooftop & process units | 8 – 120 kW | R410A / R32 · 380V 3N 50Hz | Units · LCL / FCL |
| Chillers & dry coolers | Selected by heat load | Cu/Al heat exchanger · low-noise fans | Units · modular |
| Heat pumps & heating | By water temp and load | Water-source · zoning | Packages · Scheme |
| Water-cooled chillers & GSHP | By capacity and water temp | Screw / scroll · with tower | Units · modular |
| Piping & spares | φ6.35 – φ28 | Copper · cladding · valves | Kitted to list |
Every Unit Runs Before It Ships
After assembly each unit is powered up, evacuated and charged, then run continuously at nameplate conditions with current, suction and discharge pressures and supply-air temperature logged. Bench numbers match unit serials for later traceability, and test photos or video can be supplied with the dispatch documents.
All 14 series, with catalogue data
Each series opens with capacity ranges, compressor, refrigerant, dimensions and the original catalogue PDF as datasheet.